Hewden - Need It? You Got It - The number one plant hire and equipment rental company in the UK and Europe

Power & Generator Hire

Power where you need it, when you need it. That's what you get when you hire generators from Hewden.

We're experts in generator hire with options from a 17.5kVA to a 500kVA output, with a focus on the core 20kVA to 250kVA range.

With the UK's most modern fleet of digitally controlled generators for hire nationwide, we can get you powered up whenever you need it.

The range includes road towable power generators or we deliver and position the larger generators exactly where you need them on site.

Power supply is either through a hard wire cable facility to a Hewden free standing distribution unit or through the standard range of 'plug –in' sockets including 230 volt 3pin and 400 volt 5 pin options and various current ratings.

Electronic and mechanical shut down protection and exhaust spark arrestors are standard and all units are designed for low noise operation, essential in residential areas or outdoor events and festivals.

For continuous power supply, Hewden can also provide facilities to monitor the first power supply and automatically start a back up generator in seconds.

All Hewden generators are powered by super reliable CAT diesel engines, with internal fuel tanks fully bunded. On average, internal fuel tanks last 24 hours so you can also hire an external fuel bowser or fuel tank from Hewden with up to 2200 litre capacity.

In addition, Hewden offers a fuel management service where we monitor the diesel level and make sure it never runs out.

Generators
Olympian XQE20-2 Generator Set

Olympian XQE20-2 Generator Set

kVA (kW) @ 50hz20.0 (16.0)
Engine404D-22G2
AlternatorLL1014N
Noise LWA (dBA @ 7m)89 (63.7)
Fuel Capacity ltrs (US gal)45 (12)
Consumption ltrs/hr (gal/hr)5.4 (1.4)
Running Time (hrs)8
Olympian XQE30-2 Generator Set

Olympian XQE30-2 Generator Set

kVA (kW) @ 50hz30.0 (24.0)
kVA (kW) @ 60hz34.0 (27.2)
Engine1103C-33G2/3
AlternatorLL2014B
Noise LWA (dBA @ 7m)86 (61.7)
Fuel Capacity ltrs (US gal)147 (39)
Consumption ltrs/hr (gal/hr) @ 50hz7.4 (2.0)
Consumption ltrs/hr (gal/hr) @ 60hz9.0 (2.4)
Running Time (hrs) @ 50hz18
Running Time (hrs) @ 60hz15
Olympian XQE60-2 Generator Set

Olympian XQE60-2 Generator Set

kVA (kW) @ 50hz60.0 (48.0)
kVA (kW) @ 60hz65.0 (52.0)
Engine1104C-44TG2/3
AlternatorLL2014H
Noise LWA (dBA @ 7m)87 (59.5)
Fuel Capacity ltrs (US gal)569 (150)
Consumption ltrs/hr (gal/hr) @ 50hz14.3 (3.8)
Consumption ltrs/hr (gal/hr) @ 60hz15.9 (4.2)
Running Time (hrs) @ 50hz36
Running Time (hrs) @ 60hz32
Olympian XQE80-2 Generator Set

Olympian XQE80-2 Generator Set

kVA (kW) @ 50hz80.0 (64.0)
kVA (kW) @ 60hz83.0 (66.0)
Engine1104C-44TAG1
AlternatorLL2014L
Noise LWA (dBA @ 7m)93 (64.7)
Fuel Capacity ltrs (US gal)631 (167)
Consumption ltrs/hr (gal/hr) @ 50hz18.1 (4.8)
Consumption ltrs/hr (gal/hr) @ 60hz20.2 (5.3)
Running Time (hrs) @ 50hz31
Running Time (hrs) @ 60hz28
Olympian XQE100-2 Generator Set

Olympian XQE100-2 Generator Set

kVA (kW) @ 50hz100.0 (80.0)
kVA (kW) @ 60hz106.0 (84.4)
Engine1104C-44TAG2
AlternatorLL3014B
Noise LWA (dBA @ 7m)96 (65.2)
Fuel Capacity ltrs (US gal)631 (167)
Consumption ltrs/hr (gal/hr) @ 50hz21.9 (5.8)
Consumption ltrs/hr (gal/hr) @ 60hz24.7 (6.5)
Running Time (hrs) @ 50hz26
Running Time (hrs) @ 60hz23
Olympian XQE150-2 Generator Set

Olympian XQE150-2 Generator Set

kVA (kW) @ 50hz150.0 (120.0)
kVA (kW) @ 60hz163.0 (130.0)
Engine1106C-E66TAG3
AlternatorLL3014
Noise LWA (dBA @ 7m)96 (67.2)
Fuel Capacity ltrs (US gal)822 (217)
Consumption ltrs/hr (gal/hr) @ 50hz32.5 (8.6)
Consumption ltrs/hr (gal/hr) @ 60hz37.1 (9.8)
Running Time (hrs) @ 50hz23
Running Time (hrs) @ 60hz20
Olympian XQE200-2 Generator Set

Olympian XQE200-2 Generator Set

kVA (kW) @ 50hz200.0 (160.0)
kVA (kW) @ 60hz225.0 (180.0)
Engine1306C-E87TAG4
AlternatorLL5014H
Noise LWA (dBA @ 7m)96 (69.5)
Fuel Capacity ltrs (US gal)1004 (265)
Consumption ltrs/hr (gal/hr) @ 50hz45.8 (12.1)
Consumption ltrs/hr (gal/hr) @ 60hz54.4 (14.4)
Running Time (hrs) @ 50hz20
Running Time (hrs) @ 60hz17
Olympian XQE250-2 Generator Set

Olympian XQE250-2 Generator Set

kVA (kW) @ 50hz250.0 (200.0)
Engine1306C-E87TAG6
AlternatorLL5014J
Noise LWA (dBA @ 7m)97 (68.4)
Fuel Capacity ltrs (US gal)1004 (265)
Consumption ltrs/hr (gal/hr) @ 50hz60.0 (15.9)
Running Time (hrs) @ 50hz15
Olympian GEP400-2 Generator Set

Olympian GEP400-2 Generator Set

Standby kVA (kW)400 (320)
Prime kVA (kW)350 (280)
 
Electrical Distribution
Electrical Distribution

Electrical Distribution

Our specialist electrical and lighting operation provides temporary lighting and power systems to suit a wide range of applications in industry.
 
External Lighting
External (Pro-Light) Lighting

External (Pro-Light) Lighting

Our specialist electrical and lighting operation provides temporary lighting and power systems to suit a wide range of applications in industry.
 
Catalogue_Downloads

Adobe Acrobat PDF versions of our catalogue are available for download for offline viewing/printing.

Click here to view the catalogue sections available for download...